Regulations
on Emergency Fire Pump
What is emergency fire pump ?
§ It
is a fixed emergency fire pump independently driven by self cooled compression
ignition engine or an electric motor which power is supply from emergency
generator.
§ When
all the fire pumps are out of action either by disabling the pumps or
their source of power, emergency fire pump can still be used.
Where emergency fire pump is fitted
in your ship ?
§ It
is fitted at steering flat, shaft tunnel, forward part of the ship.
§ The
pump to be located remote from machinery space.
Why emergency fire pump on board ship
?
§ It
is fitted as alternative means of providing water for fire fighting if a fire
in any one compartment could put all the fire pumps out of action either
by disabling the pumps of their source of power.
What are the requirements /
regulations for emergency fire pump ?
§ Passenger
ships of 1000 grt and upwards and in cargo ships of 2000 grt and upwards
must have fixed emergency fire pump independently driven by a self cooled
compression ignition engine or an electric motor driven by electric power
from emergency generator.
§ It
must be located outside the E/R room, in the steering flat, shaft
tunnel or in forward part of the ship.
§ It
must have own suction, total suction head should not exceed 4.5 meters under
all conditions of list or trim.
§ Pump
capacity must not less than 25m3/hr and must be able to deliver
two ½ inches bore jet of water having a horizontal throw not less than 40
ft.
§ Fuel
tank for engine shall contain sufficient fuel to run on full load for at least
3 hrs and reserve fuel for 15hrs, store outside the machinery space.
§ The
prime mover engine at that unit must be hand started and able to start by one
man.
§ If
the pump is fitted above the water level, priming arrangement must be fitted.
§ If
diesel engine driven, (a) Easily started in cold condition (zero degree C by
hand cranking ), (b) Fuel tank for engine shall contain sufficient to run
on full load for at least 3 hrs and (c) Sufficient reserve fuel for 15
hrs, store outside the machinery space.
§ If
motor driven: emergency power supply heating arrangement to be provided.
What are the requirements /
regulations for number of fire pumps on ships ?
§ Passenger
ship of 4000 GRT and upward at least 3 pumps.
§ Passenger
ship of < 4000 GRT at least 2.
§ Cargo ship of 1000 GRT & above at least 2.
§ Cargo
ship of < 1000 GRT according to administration.